Remote Control for the RCX
8,2k | 15k | 33k | 56k | ||
S1 Right |
S2 Left |
S3 go back |
S4 advance |
R | use |
0 | 0 | 0 | 0 | - | nothing |
0 | 0 | 0 | 1 | 56k | advance |
0 | 0 | 1 | 0 | 33k | move backwards |
0 | 0 | 1 | 1 | 20,8k | - |
0 | 1 | 0 | 0 | 15k | left |
0 | 1 | 0 | 1 | 11,8k | adv. and left |
0 | 1 | 1 | 0 | 10,3k | back and left |
0 | 1 | 1 | 1 | 8,7k | - |
1 | 0 | 0 | 0 | 8,2k | right |
1 | 0 | 0 | 1 | 7,2k | adv. and right |
1 | 0 | 1 | 0 | 6,6k | back and right |
1 | 0 | 1 | 1 | 5,9k | - |
1 | 1 | 0 | 0 | 5,3k | - |
1 | 1 | 0 | 1 | 4,8k | - |
1 | 1 | 1 | 0 | 4,6k | - |
1 | 1 | 1 | 1 | 4,2k | - |
We used an old remote-control of a
toy and implanted these resistorss. Attention: The sensor input
should be set to no_type and raw_mode.The raw-values of the RCX
should be noted before use. If several sensors are used on the
RCX, this will alter the returned raw-values of the
remote-control. So does the battery-level. It would be rather
helpful to write a routine which is able to fix average-values
for each function.